283 research outputs found

    Optimized techniques for real-time microwave and millimeter wave SAR imaging

    Get PDF
    Microwave and millimeter wave synthetic aperture radar (SAR)-based imaging techniques, used for nondestructive evaluation (NDE), have shown tremendous usefulness for the inspection of a wide variety of complex composite materials and structures. Studies were performed for the optimization of uniform and nonuniform sampling (i.e., measurement positions) since existing formulations of SAR resolution and sampling criteria do not account for all of the physical characteristics of a measurement (e.g., 2D limited-size aperture, electric field decreasing with distance from the measuring antenna, etc.) and nonuniform sampling criteria supports sampling below the Nyquist rate. The results of these studies demonstrate optimum sampling given design requirements that fully explain resolution dependence on sampling criteria. This work was then extended to manually-selected and nonuniformly distributed samples such that the intelligence of the user may be utilized by observing SAR images being updated in real-time. Furthermore, a novel reconstruction method was devised that uses components of the SAR algorithm to advantageously exploit the inherent spatial information contained in the data, resulting in a superior final SAR image. Furthermore, better SAR images can be obtained if multiple frequencies are utilized as compared to single frequency. To this end, the design of an existing microwave imaging array was modified to support multiple frequency measurement. Lastly, the data of interest in such an array may be corrupted by coupling among elements since they are closely spaced, resulting in images with an increased level of artifacts. A method for correcting or pre-processing the data by using an adaptation of correlation canceling technique is presented as well --Abstract, page iii

    Free-Hand Scanning and Imaging

    Get PDF
    Wideband synthetic aperture radar (SAR) imaging. A probe transmits a signal through its aperture incident to an object located in a medium of interest remotely from the probe. The probe receives through the aperture a plurality of nonuniformly sampled reflected signals from the object as the probe moves in a measurement plane located a predetermined distance from the object. A processor executes a SAR-based reconstruction algorithm to generate an image

    Darboux Transformations, Infinitesimal Symmetries and Conservation Laws for Nonlocal Two-Dimensional Toda Lattice

    Full text link
    The technique of Darboux transformation is applied to nonlocal partner of two-dimensional periodic A_{n-1} Toda lattice. This system is shown to admit a representation as the compatibility conditions of direct and dual overdetermined linear systems with quantized spectral parameter. The generalization of the Darboux transformation technique on linear equations of such a kind is given. The connections between the solutions of overdetermined linear systems and their expansions in series at singular points neighborhood are presented. The solutions of the nonlocal Toda lattice and infinite hierarchies of the infinitesimal symmetries and conservation laws are obtained.Comment: 12 pages, infinitesimal symmetries and conservation laws are adde

    Significance of Elevated Blood Metal Ion Levels in Patients with Metal-on-Metal Prostheses: An Evaluation of Oxidative Stress Markers

    Get PDF
    It is widely known that cobalt and chromium ions can enhance the production of reactive oxygen species, known to be damaging to cells by disturbing their redox status and then generating oxidative stress. The aim of the present study was to determine if increased metal ion levels induce a state of oxidative stress in patients with metal-on-metal (MM) hip arthroplasty. Results indicated that there was no significant difference in the concentration of oxidative stress markers (total antioxidants, peroxides, and nitrated proteins) in the patients with MM bearings compared to patients without prostheses. The activity antioxidant enzymes was stable (catalase and glutathione peroxidase) or slightly decreased (superoxide dismutase and heme oxygenase-1) over time. This work is the first to determine the biological effects of metal ions released from MM hip implants with regards to mid-term systemic oxidative stress and showed that the increased levels of Co and Cr ions are not associated with significant oxidative stress damage in the plasma of patients with these implants

    Lack of Evidence for the Direct Activation of Endothelial Cells by Adult Female and Microfilarial Excretory-Secretory Products

    Get PDF
    Lymphangiectasia (dilation of the lymphatic vessel (LV)) is pathognomonic for lymphatic filariasis. In both infected humans and animal models of infection, lymphangiectasia is not restricted to the site of the worm nest, but is found along the infected vessel. These observations argue that soluble products secreted by the worm could be mediating this effect by activating the lymphatic endothelial cells (LEC) lining the vessel. We tested the ability of filarial Excretory-Secretory products to activate LECs, but were unable to detect a direct effect of the Excretory-Secretory products on the activation of LEC as assessed by a variety of approaches including cellular proliferation, cell surface molecule expression and cytokine and growth factor production (although other mediators used as positive controls did induce these effects). Collectively, these results do not support the hypothesis that Excretory-Secretory products directly activate LECs

    FLT3 mutation incidence and timing of origin in a population case series of pediatric leukemia

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Mutations in <it>FLT3 </it>result in activated tyrosine kinase activity, cell growth stimulation, and a poor prognosis among various subtypes of leukemia. The causes and timing of the mutations are not currently known. We evaluated the prevalence and timing of origin of <it>FLT3 </it>mutations in a population series of childhood leukemia patients from Northern California.</p> <p>Methods</p> <p>We screened and sequenced <it>FLT3 </it>mutations (point mutations and internal tandem duplications, ITDs) among 517 childhood leukemia patients, and assessed whether these mutations occurred before or after birth using sensitive "backtracking" methods.</p> <p>Results</p> <p>We determined a mutation prevalence of 9 of 73 acute myeloid leukemias (AMLs, 12%) and 9 of 441 acute lymphocytic leukemias (ALLs, 2%). Among AMLs, <it>FLT3 </it>mutations were more common in older patients, and among ALLs, <it>FLT3 </it>mutations were more common in patients with high hyperdiploidy (3.7%) than those without this cytogenetic feature (1.4%). Five <it>FLT3 </it>ITDs, one deletion mutation, and 3 point mutations were assessed for their presence in neonatal Guthrie spots using sensitive real-time PCR techniques, and no patients were found to harbor <it>FLT3 </it>mutations at birth.</p> <p>Conclusions</p> <p><it>FLT3 </it>mutations were not common in our population-based patient series in California, and patients who harbor <it>FLT3 </it>mutations most likely acquire them after they are born.</p

    Prime movers : mechanochemistry of mitotic kinesins

    Get PDF
    Mitotic spindles are self-organizing protein machines that harness teams of multiple force generators to drive chromosome segregation. Kinesins are key members of these force-generating teams. Different kinesins walk directionally along dynamic microtubules, anchor, crosslink, align and sort microtubules into polarized bundles, and influence microtubule dynamics by interacting with microtubule tips. The mechanochemical mechanisms of these kinesins are specialized to enable each type to make a specific contribution to spindle self-organization and chromosome segregation

    Correlating preclinical animal studies and human clinical trials of a multifunctional, polymeric nanoparticle

    Get PDF
    Nanoparticles are currently being investigated in a number of human clinical trials. As information on how nanoparticles function in humans is difficult to obtain, animal studies that can be correlative to human behavior are needed to provide guidance for human clinical trials. Here, we report correlative studies on animals and humans for CRLX101, a 20- to 30-nm-diameter, multifunctional, polymeric nanoparticle containing camptothecin (CPT). CRLX101 is currently in phase 2 clinical trials, and human data from several of the clinical investigations are compared with results from multispecies animal studies. The pharmacokinetics of polymer-conjugated CPT (indicative of the CRLX101 nanoparticles) in mice, rats, dogs, and humans reveal that the area under the curve scales linearly with milligrams of CPT per square meter for all species. Plasma concentrations of unconjugated CPT released from CRLX101 in animals and humans are consistent with each other after accounting for differences in serum albumin binding of CPT. Urinary excretion of polymer-conjugated CPT occurs primarily within the initial 24 h after dosing in animals and humans. The urinary excretion dynamics of polymer-conjugated and unconjugated CPT appear similar between animals and humans. CRLX101 accumulates into solid tumors and releases CPT over a period of several days to give inhibition of its target in animal xenograft models of cancer and in the tumors of humans. Taken in total, the evidence provided from animal models on the CRLX101 mechanism of action suggests that the behavior of CRLX101 in animals is translatable to humans

    Conformational Determinants of Phosphotyrosine Peptides Complexed with the Src SH2 Domain

    Get PDF
    The inhibition of specific SH2 domain mediated protein-protein interactions as an effective chemotherapeutic approach in the treatment of diseases remains a challenge. That different conformations of peptide-ligands are preferred by different SH2 domains is an underappreciated observation from the structural analysis of phosphotyrosine peptide binding to SH2 domains that may aid in future drug design. To explore the nature of ligand binding, we use simulated annealing (SA) to sample the conformational space of phosphotyrosine-containing peptides complexed with the Src SH2 domain. While in good agreement with the crystallographic and NMR studies of high-affinity phosphopeptide-SH2 domain complexes, the results suggest that the structural basis for phopsphopeptide- Src SH2 interactions is more complex than the “two-pronged plug two-hole socket” model. A systematic study of peptides of type pYEEX, where pY is phosphotyrosine and X is a hydrophobic residue, indicates that these peptides can assume two conformations, one extended and one helical, representing the balance between the interaction of residue X with the hydrophobic hole on the surface of the Src SH2 domain, and its contribution to the inherent tendency of the two glutamic acids to form an α-helix. In contrast, a β-turn conformation, almost identical to that observed in the crystal structure of pYVNV bound to the Grb2 SH2 domain, predominates for pYXNX peptides, even in the presence of isoleucine at the third position. While peptide binding affinities, as measured by fluorescence polarization, correlate with the relative proportion of extended peptide conformation, these results suggest a model where all three residues C-terminal to the phosphotyrosine determine the conformation of the bound phosphopeptide. The information obtained in this work can be used in the design of specific SH2 domain inhibitors

    The NANOGrav 15-year data set: Search for Transverse Polarization Modes in the Gravitational-Wave Background

    Full text link
    Recently we found compelling evidence for a gravitational wave background with Hellings and Downs (HD) correlations in our 15-year data set. These correlations describe gravitational waves as predicted by general relativity, which has two transverse polarization modes. However, more general metric theories of gravity can have additional polarization modes which produce different interpulsar correlations. In this work we search the NANOGrav 15-year data set for evidence of a gravitational wave background with quadrupolar Hellings and Downs (HD) and Scalar Transverse (ST) correlations. We find that HD correlations are the best fit to the data, and no significant evidence in favor of ST correlations. While Bayes factors show strong evidence for a correlated signal, the data does not strongly prefer either correlation signature, with Bayes factors 2\sim 2 when comparing HD to ST correlations, and 1\sim 1 for HD plus ST correlations to HD correlations alone. However, when modeled alongside HD correlations, the amplitude and spectral index posteriors for ST correlations are uninformative, with the HD process accounting for the vast majority of the total signal. Using the optimal statistic, a frequentist technique that focuses on the pulsar-pair cross-correlations, we find median signal-to-noise-ratios of 5.0 for HD and 4.6 for ST correlations when fit for separately, and median signal-to-noise-ratios of 3.5 for HD and 3.0 for ST correlations when fit for simultaneously. While the signal-to-noise-ratios for each of the correlations are comparable, the estimated amplitude and spectral index for HD are a significantly better fit to the total signal, in agreement with our Bayesian analysis.Comment: 11 pages, 5 figure
    corecore